جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.
مقالوصول مفتوح2024SDG 37 استشهاد

Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study

Qamar Mohammadziad Hashem ✉،Mohammed Mustafa،Mohammed A. S. Abuelqomsan،Ahmed Sulaiman Altuwalah،Ahmed A. Almokhatieb،Mohammad Fareed،Mohmed Isaqali Karobari ✉

BMC Oral Health · مج 24 (1) · 1505-1505 · 2024

الملخّص

BACKGROUND: Coronal microleakage, the passage of fluids and bacteria through the interface between the temporary restoration and the tooth structure, can potentially result in endodontic treatment failure. PURPOSE: This study evaluated and compared the sealing efficacy of various temporary restorative materials utilized during endodontic procedures. METHODS: All seventy premolar teeth were extracted, measured, and restored, except for the negative control group, where the teeth were left whole. There were eight distinct groupings created from the teeth. Sound teeth were utilized in the n = 5 (Group 1) negative control group. A cavity after endodontic treatment was left vacant in the positive control group (n = 5, Group 2). Six experimental groups, each with ten specimens, had access cavities restored using various temporary materials (Group 3: Cavit-W, Group 4: Systemp. inlay, Group 5: Cotton + Systemp. inlay, Group 6: Cotton + Cavit-W, Group 7: Teflon + Systemp. inlay and Group 8: Teflon + Cavit-W). The teeth were submitted to thermocycling, and a microleakage test was performed. Depth of dye penetration was measured. The collected data were statistically analyzed (α = 0.05). RESULTS: Gp 7: Teflon + Systemp. inlay obtained the lowest infiltration values with no significant difference than (Gp 4: Systemp.inlay) and (Gp 8: Teflon + Cavit-W). Whereas (Gp 5: Cotton + Systemp.inlay) and (Gp 6: Cotton + Cavit-W) presented the highest significant microleakage values among other experimental groups. CONCLUSION: Regarding temporization after endodontic treatment, Teflon combined with Systemp.inlay and Cavit-W presented the best temporary materials regarding microleakage control. At the same time, cotton combined with Cavit-W presented the worst temporary material for microleakage control. Cotton is not to be used in the temporization of endodontic-treated teeth. CLINICAL IMPLICATION: Creating a tight seal in root canals that have undergone endodontic treatment is crucial for a successful, durable final restoration. Clinical and laboratory research results are an essential factor in determining how well endodontic materials seal.

التفاصيل

المجلة
BMC Oral Health
الناشر
BioMed Central
المجلد
24
العدد
1
الصفحات
1505-1505
الترقيم الدولي ISSN
1472-6831
السنة
2024
اللغة
en
الترخيص
cc-by-nc-nd
الوصول المفتوح
gold
الاستشهادات
7
المصدر
scopus

الموضوعات

InlayDentistryPremolarMedicineSignificant differenceNegative control

Endodontics and Root Canal Treatments (Dentistry) · Dental materials and restorations (Dentistry) · Periodontal Regeneration and Treatments (Medicine)

استشهد بهذا

APA
Hashem, Q. M., Mustafa, M., Abuelqomsan, M. A. S., Altuwalah, A. S., Almokhatieb, A. A., Fareed, M., Karobari, M. I. (2024). Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study. BMC Oral Health, 24(1), 1505-1505. https://doi.org/10.1186/s12903-024-05302-6
Harvard
Hashem, Q. M., Mustafa, M., Abuelqomsan, M. A. S., Altuwalah, A. S., Almokhatieb, A. A., Fareed, M., Karobari, M. I. 2024, 'Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study', BMC Oral Health, vol. 24(1), 1505-1505. Available at: https://doi.org/10.1186/s12903-024-05302-6
Vancouver
Hashem QM, Mustafa M, Abuelqomsan MAS, Altuwalah AS, Almokhatieb AA, Fareed M, Karobari MI. Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study. BMC Oral Health. 2024;24(1), 1505-1505.
BibTeX
@article{hashem20241008,
  title = {Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study},
  author = {Qamar Mohammadziad Hashem and Mohammed Mustafa and Mohammed A. S. Abuelqomsan and Ahmed Sulaiman Altuwalah and Ahmed A. Almokhatieb and Mohammad Fareed and Mohmed Isaqali Karobari},
  year = {2024},
  journal = {BMC Oral Health},
  volume = {24},
  number = {1},
  pages = {1505-1505},
  publisher = {BioMed Central},
  doi = {10.1186/s12903-024-05302-6},
  url = {https://doi.org/10.1186/s12903-024-05302-6}
}
RIS
TY  - JOUR
AU  - Qamar Mohammadziad Hashem
AU  - Mohammed Mustafa
AU  - Mohammed A. S. Abuelqomsan
AU  - Ahmed Sulaiman Altuwalah
AU  - Ahmed A. Almokhatieb
AU  - Mohammad Fareed
AU  - Mohmed Isaqali Karobari
TI  - Assessing correlation between different temporary restorative materials for microleakage following endodontic treatment: an in-vitro study
PY  - 2024
JO  - BMC Oral Health
VL  - 24
IS  - 1
SP  - 1505-1505
DO  - 10.1186/s12903-024-05302-6
UR  - https://doi.org/10.1186/s12903-024-05302-6
ER  - 

مخرجات ذات صلة