جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.
مقالوصول مفتوح2024SDG 34 استشهاد

Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking

Amany E. Abd-Eltawab،Dalia Mahmoud Abdelmonem Elsherbini ✉،Eman Mohamad El Nashar،Shaker Hassan S. Alshehri،Ali Ibrahim Alhefzi،Mamdouh Basheir Eldesoqui،Mohamed El‐Sherbiny

Frontiers in Bioengineering and Biotechnology · مج 12 · 1415645-1415645 · 2024

الملخّص

Objectives: This study determines gender variation, comparing the significance level between men and women related to functional ambulation characteristics after hip arthroplasty. The study focuses on the broader female pelvis and how it affects the rehabilitation regimen following total hip arthroplasty. Materials and Methods: In this cross-sectional study, 20 cases of right hip arthroplasty were divided into 10 male and 10 female cases, aged 40-65 years. The functional ambulation parameters (walking cadence, gait speed, stride length, and gait cycle time) were acquired from the GAITRite device, as well as kinematic values for hip frontal plane displacement and kinetic parameters for ground response force in the medial-lateral direction. Results: -test showed a significant difference in the kinematic parameter variables for the anterior superior iliac spine, more significant trochanter displacement, and hip abduction angle between the operated and non-operated limbs for each group separately. Regarding the functional ambulation parameters, there was a significant difference in the walking cadence between the operated and non-operated limbs of both male and female groups. Moreover, the output variables of ground reaction force measures revealed significant differences between their operated and non-operated limbs. The linear regression model used was consistent with the current results, demonstrating a weak negative correlation between the abduction angle of the operated hip and gait speed for both male and female groups. Conclusion: Based on the findings, we draw the conclusion that improving a rehabilitated physical therapy program for the abductors of both male and female patients' operated and non-operated limbs is essential for normalizing the ground reaction force value, avoiding focus on the operated hip, and reducing the amount of time that the operated hip's abductors must perform. This involves exposing the surgically repaired limb to the risk of post-operative displacement or dislocation, particularly in female patients.

التفاصيل

المجلة
Frontiers in Bioengineering and Biotechnology
الناشر
Frontiers Media
المجلد
12
العدد
—
الصفحات
1415645-1415645
الترقيم الدولي ISSN
2296-4185
السنة
2024
اللغة
en
الترخيص
cc-by
الوصول المفتوح
gold
الاستشهادات
4
المصدر
scopus

الموضوعات

CadenceGaitPhysical medicine and rehabilitationGround reaction forceMedicineGreater trochanter

Orthopaedic implants and arthroplasty (Medicine) · Total Knee Arthroplasty Outcomes (Medicine) · Hip disorders and treatments (Medicine)

استشهد بهذا

APA
Abd-Eltawab, A. E., Elsherbini, D. M. A., Nashar, E. M. E., Alshehri, S. H. S., Alhefzi, A. I., Eldesoqui, M. B., El‐Sherbiny, M. (2024). Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking. Frontiers in Bioengineering and Biotechnology, 12, 1415645-1415645. https://doi.org/10.3389/fbioe.2024.1415645
Harvard
Abd-Eltawab, A. E., Elsherbini, D. M. A., Nashar, E. M. E., Alshehri, S. H. S., Alhefzi, A. I., Eldesoqui, M. B., El‐Sherbiny, M. 2024, 'Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking', Frontiers in Bioengineering and Biotechnology, vol. 12, 1415645-1415645. Available at: https://doi.org/10.3389/fbioe.2024.1415645
Vancouver
Abd-Eltawab AE, Elsherbini DMA, Nashar EME, Alshehri SHS, Alhefzi AI, Eldesoqui MB, El‐Sherbiny M. Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking. Frontiers in Bioengineering and Biotechnology. 2024;12, 1415645-1415645.
BibTeX
@article{abd-eltawab20241218,
  title = {Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking},
  author = {Amany E. Abd-Eltawab and Dalia Mahmoud Abdelmonem Elsherbini and Eman Mohamad El Nashar and Shaker Hassan S. Alshehri and Ali Ibrahim Alhefzi and Mamdouh Basheir Eldesoqui and Mohamed El‐Sherbiny},
  year = {2024},
  journal = {Frontiers in Bioengineering and Biotechnology},
  volume = {12},
  pages = {1415645-1415645},
  publisher = {Frontiers Media},
  doi = {10.3389/fbioe.2024.1415645},
  url = {https://doi.org/10.3389/fbioe.2024.1415645}
}
RIS
TY  - JOUR
AU  - Amany E. Abd-Eltawab
AU  - Dalia Mahmoud Abdelmonem Elsherbini
AU  - Eman Mohamad El Nashar
AU  - Shaker Hassan S. Alshehri
AU  - Ali Ibrahim Alhefzi
AU  - Mamdouh Basheir Eldesoqui
AU  - Mohamed El‐Sherbiny
TI  - Bilateral hip stability variation in the functional ambulation and kinetic parameters after total hip arthroplasty during leveled walking
PY  - 2024
JO  - Frontiers in Bioengineering and Biotechnology
VL  - 12
SP  - 1415645-1415645
DO  - 10.3389/fbioe.2024.1415645
UR  - https://doi.org/10.3389/fbioe.2024.1415645
ER  - 

مخرجات ذات صلة