جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.
مقالوصول مفتوح20212 استشهاد

Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol

Prawez Alam،Faiyaz Shakeel،Mohammed Hamed Alqarni،Ahmed Ibrahim Foudah،Mohammed M. Ghoneim،Sultan Alshehri ✉

Separations · مج 8 (10) · 184-184 · 2021

الملخّص

The rapid, highly-sensitive and ecologically greener reversed-phase (RP)/normal-phase (NP) high-performance thin-layer chromatography (HPTLC) densitometric technique has been developed and validated for the determination of trans-resveratrol (TRV). The reversed-phase HPTLC-based analysis of TRV was performed using ethanol–water (65:35, v v−1) combination as the greener mobile phase, while, the normal-phase HPTLC-based estimation of TRV was performed using chloroform–methanol (85:15, v v−1) combination as the routine mobile phase. The TRV detection was carried out at 302 nm for RP/NP densitometric assay. The linearity was recorded as 10–1200 and 30–400 ng band−1 for RP and NP HPTLC techniques, respectively. The RP densitometric assay was observed as highly-sensitive, accurate, precise and robust for TRV detection in comparison with the NP densitometric assay. The contents of TRV in commercial formulation were recorded as 101.21% utilizing the RP densitometric assay, while, the contents of TRV in commercial formulation were found to be 91.64% utilizing the NP densitometric assay. The greener profile of RP/NP technique was obtained using the analytical GREEnness (AGREE) approach. The AGREE scales for RP and NP densitometric assays were estimated 0.75 and 0.48, respectively. The recorded AGREE scale for the RP densitometric assay indicated that this technique was highly green/the ecologically greener compared to the NP densitometric assay. After successful optimization of analytical conditions, validation parameters, AGREE scale and chromatography performance, the RP densitometric assay with univariate calibration was found to be better than the NP densitometric assay for the analysis of TRV.

التفاصيل

المجلة
Separations
الناشر
Multidisciplinary Digital Publishing Institute
المجلد
8
العدد
10
الصفحات
184-184
الترقيم الدولي ISSN
2297-8739
السنة
2021
اللغة
en
الترخيص
cc-by
الوصول المفتوح
gold
الاستشهادات
2
المصدر
scopus

الموضوعات

ChromatographyChemistryDensitometryHigh performance thin layer chromatographyCalibration curveThin-layer chromatography

Analytical Methods in Pharmaceuticals (Chemistry) · Chromatography in Natural Products (Chemistry) · Analytical Chemistry and Chromatography (Chemistry)

استشهد بهذا

APA
Alam, P., Shakeel, F., Alqarni, M. H., Foudah, A. I., Ghoneim, M. M., Alshehri, S. (2021). Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol. Separations, 8(10), 184-184. https://doi.org/10.3390/separations8100184
Harvard
Alam, P., Shakeel, F., Alqarni, M. H., Foudah, A. I., Ghoneim, M. M., Alshehri, S. 2021, 'Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol', Separations, vol. 8(10), 184-184. Available at: https://doi.org/10.3390/separations8100184
Vancouver
Alam P, Shakeel F, Alqarni MH, Foudah AI, Ghoneim MM, Alshehri S. Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol. Separations. 2021;8(10), 184-184.
BibTeX
@article{alam20212829,
  title = {Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol},
  author = {Prawez Alam and Faiyaz Shakeel and Mohammed Hamed Alqarni and Ahmed Ibrahim Foudah and Mohammed M. Ghoneim and Sultan Alshehri},
  year = {2021},
  journal = {Separations},
  volume = {8},
  number = {10},
  pages = {184-184},
  publisher = {Multidisciplinary Digital Publishing Institute},
  doi = {10.3390/separations8100184},
  url = {https://doi.org/10.3390/separations8100184}
}
RIS
TY  - JOUR
AU  - Prawez Alam
AU  - Faiyaz Shakeel
AU  - Mohammed Hamed Alqarni
AU  - Ahmed Ibrahim Foudah
AU  - Mohammed M. Ghoneim
AU  - Sultan Alshehri
TI  - Rapid, Highly-Sensitive and Ecologically Greener Reversed-Phase/Normal-Phase HPTLC Technique with Univariate Calibration for the Determination of Trans-Resveratrol
PY  - 2021
JO  - Separations
VL  - 8
IS  - 10
SP  - 184-184
DO  - 10.3390/separations8100184
UR  - https://doi.org/10.3390/separations8100184
ER  - 

مخرجات ذات صلة