Across the globe, chronic obstructive pulmonary disease (COPD) continues to be a critical healthcare burden due to its progressive and undetected decline in pulmonary function. In recent times, convolutional neural networks (CNNs) and vision transformers (ViTs) have been widely applied to lung sounds (LS) analysis, leading to the development of improved non-invasive, accessible, and scalable COPD screening methods. However, the shortcomings of CNNs and ViTs architectures restrict the COPD classifier’s discriminative power in distinguishing normal and COPD samples. In this study, a unique and interpretable COPD classification is proposed. This study introduces a hybrid feature extraction strategy integrating CNNs and ViTs architecture to capture the crucial COPD patterns from the LS’s Mel-spectrogram representation. The proposed CNNs-ViTs architecture addresses the limitations of standalone CNNs or ViTs architectures by capturing fine-grained acoustic features and long-range temporal dependencies while efficiently modeling non-linear relationships. A novel feature fusion is used to combine the heterogeneous features into a unified and highly discriminative feature representation space. A tailored hyperparameter optimization strategy is developed to fine-tune the Kolmogorov-Arnold Networks (KANs) for classifying the features into normal and COPD classes. By incorporating internal (552 Healthy and 1324 COPD LS recordings) and external (35 Healthy and 77 COPD LS recordings) datasets, the authors evaluate the model’s performance. The model achieves a generalization accuracy of 97.62% and specificity of 96.51% on the external dataset. Through Shapley Additive Explanations (SHAP) overlays, the model’s interpretability is enhanced. The experimental findings highlight the effectiveness of the proposed COPD classification architecture in the domain of biomedical acoustic signal processing. Operating with minimal reliance on specialized diagnostic infrastructure renders the proposed model ideal for primary care and resource-limited environments.
This study introduces an innovative and compact wearable Long-Range (LoRa) patch antenna developed for monitoring vital signs, with a focus on heart rate and body temperature, in medical applications of Wireless Body Area Networks (WBAN). The antenna functions within the 868 MHz and 915 MHz LoRa bands, filling a notable gap in current literature regarding compact, wearable antennas operating below 1 GHz. Fabricated on a Rogers Duroid RO3003 substrate, the antenna incorporates a U-slot on a conventional rectangular patch, a matching stub, and a partial ground plane to enhance impedance matching and performance efficiency. Furthermore, the antenna displays a bidirectional radiation pattern in the E-plane and an omnidirectional pattern in the H-plane at both frequencies, achieving a peak gain of 2.12 dBi and a radiation efficiency of 99.8% at 868 MHz. The antenna, measuring$80 \times 60 \text {mm}^{2}$($0.23~\lambda _{0} \times 0.17~\lambda _{0}$), was designed, simulated, and optimized using CST Microwave Studio (MWS) software. The performance under bending conditions was also assessed, revealing a bending an excellent efficiency with minimal impact on bandwidth and gain. Specific Absorption Rate (SAR) analysis indicated that all values were within the safety limits set by FCC and ICNIRP standards. Supervised regression machine learning models, specifically the ensemble regression model, were employed to predict resonance frequencies based on various antenna parameters, resulting in an R-squared score of 87.68%. This approach significantly reduced the computational time required for full-wave simulations, streamlining the design process. Real-world experimental validation involved open-field testing of the fabricated prototype for WBAN LoRa applications. The performance, evaluated on a LoRa transceiver system utilizing the LoRa SX1276, demonstrated the superior capabilities of the proposed antenna in heart rate and temperature monitoring, with an average RSSI improvement of -5 dBm at various points within a range of up to 1 km. This confirmed its improved signal transmission and reception capabilities in vital sign monitoring. The proposed antenna shows strong performance metrics and significant potential for WBAN in long-range applications, as evidenced by thorough experimental validations.
LoRawireless body area networksvital signs monitoringheart rate monitoring
According to the World Health Organization (WHO), congenital heart disorders (CHDs) impact a significant proportion of babies worldwide, with prevalence rates ranging from 0.8% to 1.2%. Phonocardiography (PCG) is the leading non-invasive method for detecting congenital heart defects (CHDs), offering important information about cardiac signals i.e. S1, S2, S3, and S4 and heartbeat patterns. This research study focuses on developing a strong binary classification system for congenital heart diseases (CHDs) utilizing deep neural networks. The system will be trained on a combined dataset that includes both local and publicly available repositories. The local dataset (LD) consists of 583 signals containing both normal and aberrant PCG recordings, while the public dataset (PD) obtained from Michigan University consists of 23 PCG recordings. In order to achieve consistency and compatibility, both datasets are subjected to down-sampling, resulting in a frequency of 8 kHz. A well-engineered band-pass filter efficiently removes signals outside the 20-650 Hz range, allowing for exclusive processing of the desired frequencies. The signals are divided into segments, each lasting exactly 4 seconds. The study utilizes data augmentation techniques, specifically pitch-shifting, to boost the model’s robustness. This is accomplished by implementing a 1D convolutional neural network (CNN). The most notable outcomes are achieved in case C, exhibiting a sensitivity of 99.0%, specificity of 98.0%, F1 score of 98.56%, precision of 98.57%, and an accuracy of 98.56%. This study enhances the progress of automated techniques for detecting congenital heart disease (CHD), demonstrating the potential of deep neural networks in precision medicine for pediatric cardiology.
Osteosarcoma is the most normal kind of cancer that arises in bones, which appears on the surface to resemble earlier types of bone cells that assist in forging new bone tissues, but the tissue in osteosarcoma is weaker and softer than normal bone tissue. The usage of automated techniques for the detection of osteosarcoma has the potential to mitigate the obligations and burdens confronted by pathologists owing to its abundant quantity of cases. Artificial intelligence (AI) has an emerging progress in diagnostic pathology. In recent years, numerous studies using deep learning (DL) techniques to histopathological images (HI) have been published. While several studies claim higher accuracy, they might lack generalization and fall into the pitfall of overfitting owing to the wide range of HI. The study objective is to enhance the diagnosis and detection of osteosarcoma by employing computer-assisted detection (CAD) and diagnoses (CADx). Technique like convolutional neural networks (CNN) make better prognoses for patient conditions and considerably reduce the surgeon’s workload. CNN needs to be trained on the massive quantity of data to accomplish a remarkable performance. Therefore, the study presents a novel Group Teaching Optimization Algorithm with Deep Learning-Driven Osteosarcoma Detection on Histopathological Images (GTOADL-ODHI) technique. The purpose of the GTOADL-ODHI technique is to examine the HIs for the detection and classification of osteosarcoma. To accomplish this, the GTOADL-ODHI algorithm applies the Gaussian filtering (GF) method for image pre-processed to become rid of the noise. Besides, the capsule network (CapsNet) model is utilized for the extractor of the feature vector. Furthermore, the hyperparameter selection of the CapsNet approach takes place using the GTOA. Finally, the self-attention bidirectional long short-term memory (SA-BiLSTM) model can be employed for osteosarcoma recognition and classification. The widespread experimental analysis of the GTOADL-ODHI method is tested on the benchmark datasets. The simulation validation reported the optimum solution of the GTOADL-ODHI algorithm related to existing systems concerning distinct aspects.
Recent events dedicated to e-healthcare systems demonstrated that a critical mass of users using e-health services and applications are being created and producing a tremendous output, such as improved patient monitoring, faster diagnosis, and better disease management. However, despite the benefits and availability of e-health systems, widespread adoption in real-life medical or health situations still needs to be improved. Therefore, implementing a four-party authentication system can help address concerns about security and privacy and encourage patients to adopt electronic healthcare technologies. This article presents a security protocol for securely authenticating four participants in the e-healthcare system, namely LSP–eHS. The scheme uses a simple cryptographic hash function, concatenation, and xor operations. The security of the proposed protocol can be confirmed through a widely used BAN (Burrows–Abadi–Needham) logic, and the performance analysis of the proposed protocol can be finished by measuring communication and computation costs.
This paper presents a unique antenna that is designed to be efficient, with improved gain and partial flexibility, for use in wearable biomedical telemetry applications. The antenna design utilizes a semi-flexible RO5880 substrate material (dielectric constant, εr= 2.2, loss tangent, (tan δ) = 0.0009) with physical dimensions measuring 0.47λg× 0.47λg. The model involves the incorporation of rectangular inverted "C" slots, which effectively results in a reduction of the resonant frequency. Additionally, a distributed rectangular slot is introduced on the ground plane, contributing to the augmentation of the operational bandwidth. The operational frequency of the proposed antenna design is 2.40 GHz, accompanied by a bandwidth (BW) of 320 MHz at a -10 dB level. This equates to a fractional percentage bandwidth (FBW) of 13.33% centered around the frequency of 2.40 GHz. The antenna design presented in this work demonstrates the preservation of improved gain and efficiency, achieving values of 3.67 dBi and 94%, respectively, at a frequency of 2.40 GHz. The work demonstrates through simulation and experimental outcomes that the antenna exhibits minimal impact on parameters such as gain reflection coefficient (|S11|), BW, and bending efficiency. Furthermore, the antenna underwent simulation and experimental testing in close proximity to the human body, revealing favorable operational characteristics. The proposed antenna exhibits substantial potential as a viable option for wearable biomedical instruments. Thus, the proposed wearable antenna design in this study offers a wideband antenna for ISM band applications, expanding bandwidth without compromising performance. Bending the antenna minimally affects gain, bandwidth, and efficiency when worn on the body, making it suitable for wearables. It also maintains a reasonably low Specific Absorption Rate (SAR), reducing wave absorption by the body. Unique features like rectangular inverted "C" slots and a distributed rectangular slot on the ground plane enhance bandwidth while maintaining performance during bending.
wearable antennaswireless body area networksbiotelemetry2.4 GHz
Telecare Medical Information Systems (TMIS) is a highly focused and unique domain providing healthcare services remotely, the development and advancement in the realm of information and communication technologies boosted the development of TMIS. Smartphones, IoT devices, Mobile Healthcare Applications (MHA) and hospital servers are the building blocks of TMIS. Emergen Research predicts that IoT based healthcare security market will reach USD 5.52 Billion in 2028. Existing IoT based healthcare solutions are facing many security problems which includes information leakage, false authentication, key loss and are not in compliance with Health Insurance Portability and Accountability Act (HIPAA) regulations as IoT devices and sensors used are prone to Blue Borne, DoS (Denial of Service), DDoS (Distributed Denial of Service) and Reverse-engineering attacks. In addition to these healthcare applications in the IoT devices/sensors and mobile healthcare applications in the smart phone of the patient are vulnerable to repackaging attacks and lacked transport layer protection. This paper proposes a SRSTMIS (Secure and Resilient Scheme for Telecare Medical Information Systems) containing its architecture, a procedure to verify the safety and security of patients credentials and Mobile Healthcare Applications (MHA) and finally proposed a secure protocol. White-Box Cryptography (WBC) ensures the safety and security of the keys in the healthcare applications and in the SE, UICC and TPM. We have threat modeled our proposed healthcare framework using STRIDE approach and successfully verified using Microsoft Threat Modeling tool 2016. Our proposed secure and lightweight authentication scheme has been successfully verified with BAN (Burrows, Abadi, and Needham) logic and Scyther tool, and our proposed protocol overcome DoS (Denial of Service), multi-protocol attack, Blue Borne attack, DDoS (Distributed Denial of Service) attack, reverse engineering, insider, outsider and Phlashing attacks. SRSTMIS overcomes information leakage from sensors during rest and during transit, key loss from healthcare applications of the sensors and smart phone and false authentication and ensures HIPAA regulations. Proposed protocol was successfully implemented in Android Studio. We have compared our proposed work with the existing works and found to better in terms of security, resisting attacks, and in consumption of resources.
telecare medical information systemsmobile health appslightweight authentication protocolwhite-box cryptography