جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

2 مُخرَج نتائج البحث عن «biomedical implants»

مقالوصول مفتوح20253استشهاد· Semantic Scholar

A Compact Implantable Multiple-Input-Multiple-Output Antenna for Biotelemetry and Sensing Applications

Sensors · مجلد 25 (11) · 3323-3323

Gastrointestinal (GI) tract diseases are among the most common diseases in the world, resulting in more than 8 million deaths. The majority of these deaths occur due to cancer or tumors. Early detection of these tumors can greatly lower the mortality rate. In this work, an implantable multiple-input-multiple-output (MIMO) antenna sensor is constructed for GI tract devices to detect the tumor. The implantable MIMO antenna sensor has two embedded antennas, each operating at 915 MHz. Both elements of the system are placed 0.6 mm apart from each other (edge-to-edge). The volume consumed by this design is measured to be 7 × 7 × 0.25 = 12.25 mm3. It occupies a very small volume due to miniaturization achieved using meandered resonating structures and a high-permittivity substrate. It maintains stable radiation performance (gain = −26.2 dBi at resonance). The antenna units are decoupled by maintaining a proper gap between them and adding a slot on the bottom side. An isolation level greater than 28.7 dB is achieved using these approaches. Since the MIMO system utilizes two antenna elements, its effectiveness is verified using MIMO parameters. At SNR = 20 dB, the channel capacity reaches 8.75 bps/Hz. The proposed antenna ensures high channel capacity and enables seamless communication while simultaneously acting as a sensor to monitor internal changes in the observed region. The frequency response change with variations in the permittivity of human tissue, enabling its sensing capability. Moreover, the antenna sensor maintains stable radiation and S-parameter performance throughout the sensing mechanism. Thus, the proposed solution is suitable for biomedical implants requiring both high-data-rate communication and sensing.

implantable antennaMIMO antennaantenna sensorbiotelemetry
مقالوصول مفتوح202314استشهاد· Semantic Scholar

A multiband SSr diode RF rectifier with an improved frequency ratio for biomedical wireless applications

Scientific Reports · مجلد 13 (1) · 13246-13246

This paper described a four-band implantable RF rectifier with simplified circuit complexity. Each RF-rectifier cell is sequentially matched to the four operational frequencies to accomplish the proposed design. The proposed RF rectifier can harvest RF signals at 1.830, 2.100, and white space Wi-Fi bands between 2.38 to 2.68 GHz, respectively. At 2.100 GHz, the proposed RF harvester achieved a maximum (radio frequency direct current) RF-to-DC power conversion efficiency (PCE) of 73.00% and an output DC voltage [Formula: see text] of 1.61 V for an RF power of 2 dBm. The outdoor performance of the rectenna shows a [Formula: see text] of 0.440 V and drives a low-power bq25504-674 evaluation module (EVM) at 1.362 V. The dimension of the RF-rectifier on the FR-4 PCB board is 0.27[Formula: see text] [Formula: see text] 0.29[Formula: see text]. The RF-rectifier demonstrates the capacity to effectively utilize the frequency domain by employing multi-band operation and exhibiting a good impedance bandwidth through a sequential matching technique. Thus, by effectively controlling the rectenna's ambient performance, the proposed design holds the potential for powering a range of low-power biomedical implantable devices. (BIDs).

RF rectifierrectennamultiband operationbiomedical implants