جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

2 مُخرَج نتائج البحث عن «noise reduction»

مقالوصول مفتوح202516استشهاد· Semantic Scholar

Enhancing pediatric congenital heart disease detection using customized 1D CNN algorithm and phonocardiogram signals

Heliyon · مجلد 11 (3) · e42257-e42257

Congenital heart disease (CHD), impacting around 1 % of infants worldwide, constitutes a significant healthcare challenge. Early detection is crucial, however constrained by the intricacies of conventional diagnostic techniques such as auscultation and echocardiography. This research presents a tailored one-dimensional convolutional neural network (1D-CNN) for the classification of phonocardiogram (PCG) signals into normal or abnormal categories, providing an automated and efficient solution for congenital heart disease (CHD) diagnosis. The model was trained on a composite dataset consisting of local pediatric PCG signals and publicly accessible dataset. Preprocessing methods, such as low- and high-pass filtering (60-650 Hz), resampling, and noise reduction, were utilized to enhance signal quality. Data augmentation techniques, including chunking, padding, and pitch-shifting, were employed to rectify dataset imbalances and improve model efficacy. Experimental results indicate substantial enhancements, attaining an accuracy of 98.56 %, precision of 98.56 %, F1 score of 98.55 %, sensitivity of 0.98, and specificity of 0.99. The comparative analysis demonstrates the proposed approach's superiority over current methods regarding accuracy and reliability. The research highlights the promise of combining modern signal processing with deep learning for efficient CHD screening. The suggested model exhibits outstanding performance yet, issues like dataset variability and noise persist. Future endeavors involve extending to multiclass categorization and assessing performance across a wider range of medical problems. This study represents a significant advancement in accessible, automated CHD diagnoses, enhancing clinical competence to elevate pediatric treatment.

congenital heart diseasephonocardiogram1D convolutional neural networkpediatric cardiology
مقالمفتوح (مستودع)20251استشهاد· Semantic Scholar

Enhancing Diagnostic Precision: A Distribution-Based Compressed Denoising Scheme using Transfer Learning for Noise Reduction in Medical Imaging

Current Medical Imaging Formerly Current Medical Imaging Reviews · مجلد 21 · e15734056391923-e15734056391923

INTRODUCTION: Accurate interpretation of medical images is vital for diagnosis and treatment planning. However, noise in medical imaging significantly hampers this process, leading to potential diagnostic errors. Traditional denoising techniques often require large datasets or compromise diagnostic details. METHOD: This study proposes a Distribution-based Compressed Denoising Scheme (DCDS) leveraging transfer learning to enhance diagnostic precision. The framework analyzes pixel distributions to distinguish normal and noisy pixels using incremental and decremental distribution verification. A chest CT scan dataset with Gaussian-like noise was used to train the model, employing correlation mapping between training and target images for effective variance estimation. RESULT: Experimental analysis showed that DCDS significantly improves noise reduction, variance detection, and diagnostic precision. The peak signal-tonoise ratio improved across all evaluated ranges (24-32 dB), with a noise reduction rate exceeding 82% in optimal conditions. DCDS reduced mean error and analysis time, enhancing overall system efficiency. Transfer learning allowed for effective pixel classification and noise prediction with fewer data and computational resources. DISCUSSION: Compared to existing denoising methods, DCDS offers better generalization through statistical modeling and knowledge-sharing between training and learning states. However, current validation is limited to CT imaging with Gaussian noise. Broader modality testing and integration of perceptual and clinical grading metrics are needed. CONCLUSION: The DCDS framework presents a promising, lightweight, adaptive, and accurate solution for medical image denoising. It holds potential for realtime diagnostic support, but further optimization and clinical validation are necessary to ensure generalizability across diverse imaging modalities and noise types.

medical image denoisingtransfer learningchest CTGaussian noise