جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.
NA

Nasser Ali Aljarallah

بانتظار توثيق الانتساب2022–2026
21وثائق Scopus
156استشهاداً
9مؤشر h
0منها بانتماء الجامعة
إجمالي Scopus (كل الجهات)
مقالوصول مفتوح20261استشهاد· Semantic Scholar

Diabetic retinopathy severity detection using an improved Whale optimization algorithm and convolutional Kolmogorov-Arnold network

Frontiers in Medicine · مجلد 13 · 1709872-1709872

Introduction: Diabetic retinopathy (DR) is an inflammatory condition affecting the retina caused by elevated and unregulated blood glucose levels. On a global scale, it is a contributing factor to vision impairment. Several deep learning (DL) methods use retinal images to identify DR severity. However, a significant improvement is required to assist medical professionals in recognizing DR in its early phases. Methods: Thus, the author introduced a method based on the DL technique to determine the DR severity grades using retinal images. A ShuffleNet V2 model with vision transformers' (ViT) attention mechanism was used to extract the features. An improved Whale optimization method (IWO) was used to fine-tune the feature extraction model. We employed a convolutional Kolmogorov-Arnold Network to categorize the DR severity using the extracted features. The EyePACS dataset was utilized to train the proposed DR severity grading model using a five-fold cross-validation strategy. We generalized the model on the Messidor-2 dataset. Results: The findings revealed an average accuracy of 93.84% on the MESSIDOR-2 dataset, demonstrating a substantial improvement in detecting DR using the fundus images. Discussion: Furthermore, the model demands minimal processing resources to generate the outcomes, leading to the deployment of the proposed DR severity detection model in healthcare facilities with limited computational resources.

diabetic retinopathyseverity classificationfundus imageswhale optimization algorithm
مقالوصول مفتوح2026

VG-RETFound: a hybrid retinal AI framework for early vision impairment screening through vessel-graph learning and cross-modal fusion

Frontiers in Medicine · مجلد 13 · 1905129-1905129

Introduction: Vision impairment caused by retinal diseases stands out as one of the significant sources of irreversible blindness, highlighting the importance of developing robust automated screening tools to detect eye diseases at an early stage. Despite the promising results of recent deep learning approaches to the automatic classification of retinal images, most existing solutions focus on image-based representations and do not consider the importance of vascular topology. To overcome the limitations, this study proposes VG-RETFound - a hybrid framework based on a retinal foundation model and graph-based vascular-topology modeling that can be used to classify multiple retinal categories and detect vision impairment. Methods: The authors use RETFound-a retinal foundation model-pretrained on a vast number of retinal images, as well as the Graph Attention Network (GAT), to learn vascular topology features by representing retinal vessels as graphs. The presented approach employs a cross-modal multi-head attention fusion method to integrate features from both modalities in real time. To evaluate the efficiency of VG-RETFound, experiments were conducted using the RFMiD and ODIR-5 K datasets for model training and testing across six retinal categories: Normal, Diabetic Retinopathy, Pathological Myopia, Age-related Macular Degeneration, Hypertensive Retinopathy, and Other Retinal Diseases. Results: The accuracy of 96.39%, F1-score of 95.84%, MCC of 94.87%, and Kappa of 94.71% were attained on an internal test dataset, while cross-dataset external validation on the BRSET dataset revealed accuracy of 94.81%, F1-score of 94.25%, MCC of 93.09%, and Kappa of 92.94%. Discussion: These findings demonstrate that integrating retinal foundation models with anatomically informed vessel-topology learning significantly improves classification accuracy, interpretability, and generalization, highlighting the potential of VG-RETFound as a tool for large-scale vision impairment. screening and retinal disease diagnosis.

retinal disease classificationRETFoundgraph attention networksvascular topology
مقالوصول مفتوح202510استشهاد· Semantic Scholar

Image classification-driven speech disorder detection using deep learning technique

SLAS TECHNOLOGY · مجلد 32 · 100261-100261

Speech disorders affect an individual's ability to generate sounds or utilize the voice appropriately. Neurological, developmental, physical, and trauma may cause speech disorders. Speech impairments influence communication, social interaction, education, and quality of life. Successful intervention entails early and precise diagnosis to allow for prompt treatment of these conditions. However, clinical examinations by speech-language pathologists are time-consuming, subjective, and demand an automated speech disorder detection (SDD) model. Mel-spectrogram images present a visual representation of multiple speech disorders. By classifying Mel-Spectrogram, various speech disorders can be identified. In this study, the authors proposed an image classification-based automated SDD model to classify Mel-Spectrograms to identify multiple speech disorders. Initially, Wavelet Transform (WT) hybridization technique was employed to generate Mel-Spectrogram using the voice samples. A feature extraction approach was developed using an enhanced LEVIT transformer. Finally, the extracted features were classified using an ensemble learning (EL) approach, containing CatBoost and XGBoost as base learners, and Extremely Randomized Tree as a meta learner. To reduce the computational resources, the authors used quantization-aware training (QAT). They employed Shapley Additive Explanations (SHAP) values to offer model interpretability. The proposed model was generalized using Voice ICar fEDerico II (VOICED) and LANNA datasets. The exceptional accuracy of 99.1 with limited parameters of 8.2 million demonstrated the significance of the proposed approach. The proposed model enhances speech disorder classification and offers novel prospects for building accessible, accurate, and efficient diagnostic tools. Researchers may integrate multimodal data to increase the model's use across languages and dialects, refining the proposed model for real-time clinical and telehealth deployment.

Mel spectrogramwavelet transformfeature extractionensemble learning
مقالوصول مفتوح20251استشهاد· Semantic Scholar

MultiEpilepsyNet: An EEG and MRI data based multimodal seizure detection model using hybrid deep learning model

Brain Research Bulletin · مجلد 233 · 111645-111645

Epilepsy is a critical neurological disorder that requires accurate and privacy-preserving diagnostic solutions to enable early detection and effective management. However, existing approaches face key challenges, including reliance on centralized data, poor generalizability across modalities, suboptimal feature extraction, and vulnerability to noise. To address these issues, we propose MultiEpilepsyNet, a novel multimodal seizure detection framework that integrates federated learning with hybrid deep learning models. At its core, the system introduces SeizureFed-Net, a federated architecture that enables collaborative learning from EEG and MRI data while safeguarding patient privacy. For detection, we design SeizureShieldNet, a hybrid model that fuses the temporal learning capabilities of BBIDNet (Boosted BiLSTM Intrusion Detector Network) with the adaptive decision-making of FD-TMS (Fuzzy-DQN Threat Mitigation System) under uncertainty. To further enhance model efficiency, a Jackal-Wolf Hybrid Optimizer (JWHO)-a novel combination of Golden Jackal Optimization and Grey Wolf Optimizer-is employed for optimal feature subset selection. On the imaging side, MRI preprocessing is improved through EpiSkullNet+ +, a modified 3D UNet+ + architecture tailored for precise brain segmentation. Extensive experiments on two benchmark datasets demonstrate the superiority of our approach, achieving 99.36 % accuracy on the CHB-MIT EEG dataset and 99.38 % accuracy on an epilepsy MRI dataset. Beyond accuracy, MultiEpilepsyNet demonstrates improved robustness to missing modalities, reduced training overhead via federated aggregation, and enhanced privacy preservation compared to centralized deep learning models, thereby addressing critical barriers in practical clinical deployment. These outcomes highlight the effectiveness, scalability, and real-world clinical potential of the proposed framework for epilepsy diagnosis and management.

epilepsyseizure detectionmultimodal fusionEEG
نسخة أوليةمفتوح (مستودع)2025

RNA-seq Data Generation and 1D-CNN Classification Workflow for Visual Impairment Research v1

—

A robust, reproducible pipeline to (i) generate realistic synthetic RNA-seq data for visual-impairment research using a Negative Binomial model, (ii) build and train a 1D-CNN classifier, (iii) evaluate performance via ROC-AUC and SHAP interpretability, and (iv) publish both code and datasets to public repositories (Protocols.io & NCBI GEO).

visual impairmentnegative binomial regressionSHAParea under the receiver operating characteristic
مراجعةوصول مفتوح202411استشهاد· Semantic Scholar

A Systematic Review of Genetics- and Molecular-Pathway-Based Machine Learning Models for Neurological Disorder Diagnosis

International Journal of Molecular Sciences · مجلد 25 (12) · 6422-6422

The process of identification and management of neurological disorder conditions faces challenges, prompting the investigation of novel methods in order to improve diagnostic accuracy. In this study, we conducted a systematic literature review to identify the significance of genetics- and molecular-pathway-based machine learning (ML) models in treating neurological disorder conditions. According to the study's objectives, search strategies were developed to extract the research studies using digital libraries. We followed rigorous study selection criteria. A total of 24 studies met the inclusion criteria and were included in the review. We classified the studies based on neurological disorders. The included studies highlighted multiple methodologies and exceptional results in treating neurological disorders. The study findings underscore the potential of the existing models, presenting personalized interventions based on the individual's conditions. The findings offer better-performing approaches that handle genetics and molecular data to generate effective outcomes. Moreover, we discuss the future research directions and challenges, emphasizing the demand for generalizing existing models in real-world clinical settings. This study contributes to advancing knowledge in the field of diagnosis and management of neurological disorders.

neurological disordersmachine learning modelsgenetic datamolecular pathways
مراجعةوصول مفتوح20241استشهاد· Semantic Scholar

A Systematic Review on Developing Computer Programming Skills for Visually Impaired Students

Journal of Disability Research · مجلد 3 (2)

Technology and digital-based learning drive contemporary computer skill (CS) education advances. The absence of resources that are easily accessible and tailored to help the development of conceptual understanding in computers may present a number of issues for students who have visual impairments (VI) in the context of CS education. The objective of the research was to provide a concise overview of the existing evidence-based information about CS instruction for students with severe VI. A systematic review was performed to analyze the research papers published between January 2000 and September 2023. A total of 21 articles were extracted and classified into assistive technologies (ATs) and CSs. The study findings highlight the significance of the development of ATs and effective course design for supporting individuals with VI. It can be used by policy makers and educational institutions to present a useful environment for individuals with VI to improve their CSs. In future, the authors need to focus on ATs to enhance the computer programming abilities of students with VI. In addition, they will develop programming platforms and integrated development environments that are easily accessible and can be customized to meet a wide range of learning requirements.

visual impairmentprogramming skillsassistive technologyaccessible computing
مقالوصول مفتوح202339استشهاد· Semantic Scholar

Satisfaction of patients with health care services in tertiary care facilities of Riyadh, Saudi Arabia: A cross-sectional approach

Frontiers in Public Health · مجلد 10 · 1077147-1077147

As part of Saudi Vision 2030, the country's healthcare system is undergoing a significant makeover, with accessibility and effectiveness serving as the benchmarks for measuring patient care quality. This study's goal was to ascertain the degree of patient satisfaction with the medical care and services received in Riyadh's tertiary care facilities. The PSQ-18 (Patient Satisfaction Questionnaire-18), a standardized validated questionnaire including areas of “overall satisfaction,” “technical quality,” “interpersonal aspect,” “communication,” “financial aspect,” “time spent with the doctor,” and “accessibility and convenience,” was used in this cross-sectional study on 384 patients of two tertiary care facilities in Riyadh, Saudi Arabia, over a 6-month period. The degree to which sociodemographic characteristics and components of patient satisfaction are correlated was assessed using binary and multiple regression analysis. When the P-value was < 0.05, the results were considered significant and were presented as adjusted odds ratios (AOR). To ascertain how each PSQ-18 subscale affected other subscales, a Pearson Correlation analysis was conducted. The overall degree of satisfaction with all 18 items was 73.77%. The financial component received a rating of 81% compared to 77% for general satisfaction. Technical quality (75%) was followed by accessibility and convenience (73.5%), communication (73%), and interpersonal elements (72%). At 68%, the time spent in the doctor's domain received the lowest rating. The odds of satisfaction were increased by 3.87 times, 3.45 times, and 3.36 times among those who are employed, qualified by university education, and married compared to unemployed (P-value = 0.018), less qualified (P-value = 0.015) and singles (P-value = 0.026), respectively. The younger age group also made 1.78 times more of a difference in higher satisfaction ratings. The general satisfaction domain showed a positive association with other areas. Participants who were satisfied with the communication and accessibility and convenience domains of healthcare providers were the only ones who were typically satisfied with the domain of doctor time spent. The study's findings could act as a benchmark for Saudi Arabia's healthcare services as well as a starting point for quality assurance procedures.

patient satisfactiontertiary carequality of carephysician-patient communication
مقالوصول مفتوح202318استشهاد· Semantic Scholar

Advancement of a High-Efficiency Wearable Antenna Enabling Wireless Body Area Networks

IEEE Access · مجلد 11 · 138325-138335

This paper presents a unique antenna that is designed to be efficient, with improved gain and partial flexibility, for use in wearable biomedical telemetry applications. The antenna design utilizes a semi-flexible RO5880 substrate material (dielectric constant, εr= 2.2, loss tangent, (tan δ) = 0.0009) with physical dimensions measuring 0.47λg× 0.47λg. The model involves the incorporation of rectangular inverted "C" slots, which effectively results in a reduction of the resonant frequency. Additionally, a distributed rectangular slot is introduced on the ground plane, contributing to the augmentation of the operational bandwidth. The operational frequency of the proposed antenna design is 2.40 GHz, accompanied by a bandwidth (BW) of 320 MHz at a -10 dB level. This equates to a fractional percentage bandwidth (FBW) of 13.33% centered around the frequency of 2.40 GHz. The antenna design presented in this work demonstrates the preservation of improved gain and efficiency, achieving values of 3.67 dBi and 94%, respectively, at a frequency of 2.40 GHz. The work demonstrates through simulation and experimental outcomes that the antenna exhibits minimal impact on parameters such as gain reflection coefficient (|S11|), BW, and bending efficiency. Furthermore, the antenna underwent simulation and experimental testing in close proximity to the human body, revealing favorable operational characteristics. The proposed antenna exhibits substantial potential as a viable option for wearable biomedical instruments. Thus, the proposed wearable antenna design in this study offers a wideband antenna for ISM band applications, expanding bandwidth without compromising performance. Bending the antenna minimally affects gain, bandwidth, and efficiency when worn on the body, making it suitable for wearables. It also maintains a reasonably low Specific Absorption Rate (SAR), reducing wave absorption by the body. Unique features like rectangular inverted "C" slots and a distributed rectangular slot on the ground plane enhance bandwidth while maintaining performance during bending.

wearable antennaswireless body area networksbiotelemetry2.4 GHz
مقالوصول مفتوح202314استشهاد· Semantic Scholar

A multiband SSr diode RF rectifier with an improved frequency ratio for biomedical wireless applications

Scientific Reports · مجلد 13 (1) · 13246-13246

This paper described a four-band implantable RF rectifier with simplified circuit complexity. Each RF-rectifier cell is sequentially matched to the four operational frequencies to accomplish the proposed design. The proposed RF rectifier can harvest RF signals at 1.830, 2.100, and white space Wi-Fi bands between 2.38 to 2.68 GHz, respectively. At 2.100 GHz, the proposed RF harvester achieved a maximum (radio frequency direct current) RF-to-DC power conversion efficiency (PCE) of 73.00% and an output DC voltage [Formula: see text] of 1.61 V for an RF power of 2 dBm. The outdoor performance of the rectenna shows a [Formula: see text] of 0.440 V and drives a low-power bq25504-674 evaluation module (EVM) at 1.362 V. The dimension of the RF-rectifier on the FR-4 PCB board is 0.27[Formula: see text] [Formula: see text] 0.29[Formula: see text]. The RF-rectifier demonstrates the capacity to effectively utilize the frequency domain by employing multi-band operation and exhibiting a good impedance bandwidth through a sequential matching technique. Thus, by effectively controlling the rectenna's ambient performance, the proposed design holds the potential for powering a range of low-power biomedical implantable devices. (BIDs).

RF rectifierrectennamultiband operationbiomedical implants