Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis

Tariq Mohammed Aljarba،Faiyaz Shakeel،Sultan Alshehri ✉،Muzaffar Iqbal،Ahmed Ibrahim Foudah،Mohammed Hamed Alqarni،Ali Alhaiti،Fatma Mohamed Abdel Bar،Prawez Alam ✉

Arabian Journal of Chemistry · مج 17 (7) · 105837-105837 · 2024

الملخّص

There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.

التفاصيل

المجلة
Arabian Journal of Chemistry
الناشر
Elsevier BV
المجلد
17
العدد
7
الصفحات
105837-105837
الترقيم الدولي ISSN
1878-5352
السنة
2024
اللغة
en
الترخيص
cc-by-nc-nd
الوصول المفتوح
hybrid
الاستشهادات
3
المصدر
scopus

الموضوعات

ChemistryChromatographyStationary phaseHigh performance thin layer chromatographyThin-layer chromatography

Analytical Methods in Pharmaceuticals (Chemistry) · Analytical Chemistry and Chromatography (Chemistry) · Forensic Toxicology and Drug Analysis (Pharmacology, Toxicology and Pharmaceutics)

استشهد بهذا

APA
Aljarba, T. M., Shakeel, F., Alshehri, S., Iqbal, M., Foudah, A. I., Alqarni, M. H., Alhaiti, A., Bar, F. M. A., Alam, P. (2024). Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis. Arabian Journal of Chemistry, 17(7), 105837-105837. https://doi.org/10.1016/j.arabjc.2024.105837
Harvard
Aljarba, T. M., Shakeel, F., Alshehri, S., Iqbal, M., Foudah, A. I., Alqarni, M. H., Alhaiti, A., Bar, F. M. A., Alam, P. 2024, 'Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis', Arabian Journal of Chemistry, vol. 17(7), 105837-105837. Available at: https://doi.org/10.1016/j.arabjc.2024.105837
Vancouver
Aljarba TM, Shakeel F, Alshehri S, Iqbal M, Foudah AI, Alqarni MH, Alhaiti A, Bar FMA, Alam P. Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis. Arabian Journal of Chemistry. 2024;17(7), 105837-105837.
BibTeX
@article{aljarba20241372,
  title = {Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis},
  author = {Tariq Mohammed Aljarba and Faiyaz Shakeel and Sultan Alshehri and Muzaffar Iqbal and Ahmed Ibrahim Foudah and Mohammed Hamed Alqarni and Ali Alhaiti and Fatma Mohamed Abdel Bar and Prawez Alam},
  year = {2024},
  journal = {Arabian Journal of Chemistry},
  volume = {17},
  number = {7},
  pages = {105837-105837},
  publisher = {Elsevier BV},
  doi = {10.1016/j.arabjc.2024.105837},
  url = {https://doi.org/10.1016/j.arabjc.2024.105837}
}
RIS
TY  - JOUR
AU  - Tariq Mohammed Aljarba
AU  - Faiyaz Shakeel
AU  - Sultan Alshehri
AU  - Muzaffar Iqbal
AU  - Ahmed Ibrahim Foudah
AU  - Mohammed Hamed Alqarni
AU  - Ali Alhaiti
AU  - Fatma Mohamed Abdel Bar
AU  - Prawez Alam
TI  - Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis
PY  - 2024
JO  - Arabian Journal of Chemistry
VL  - 17
IS  - 7
SP  - 105837-105837
DO  - 10.1016/j.arabjc.2024.105837
UR  - https://doi.org/10.1016/j.arabjc.2024.105837
ER  - 

مخرجات ذات صلة