Almaarefa University
The authoritative source for research information and outputs is Elsevier Scopus, with researcher profile verification from the Deanship of Scientific Research.
ArticleOpen (repository)20243 citation

Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis

Tariq Mohammed Aljarba،Faiyaz Shakeel،Sultan Alshehri ✉،Muzaffar Iqbal،Ahmed Ibrahim Foudah،Mohammed Hamed Alqarni،Ali Alhaiti،Fatma Mohamed Abdel Bar،Prawez Alam ✉

Arabian Journal of Chemistry · vol. 17 (7) · 105837-105837 · 2024

Abstract

There are very limited analytical procedures to determine lemborexant (LMB) in dosage forms and biological materials. However, the literature does not provide any “high-performance thin-layer chromatographic (HPTLC)” assays to determine LMB. In an effort to analyze LMB in commercial pharmaceutical tablets more precisely, accurately, and sustainably than with the normal-phase-HPTLC (NP-HPTLC) approach, a sensitive and greener reverse-phase-HPTLC (RP-HPTLC) method was developed and validated. For NP-HPTLC, an acetone-petroleum ether (40:60 v/v) developing system was used. However, ethanol–water (85:15 v/v) was the developing system for RP-HPTLC. Four different techniques, including the National Environmental Method Index (NEMI), Analytical Eco-Scale (AES), ChlorTox, and Analytical GREENness (AGREE), were used to evaluate the greenness of both procedures. LMB measurement was linear in the 50–500 and 20–1000 ng/band ranges, respectively for NP and RP procedures. RP procedure was more robust (uncertainties = 0.90–0.95 %), accurate (recoveries = 98.24–101.57 %), precise (uncertainties = 0.87–1.00 %), linear (20–1000 ng/band), sensitive (LOD = 0.92 ng/band and LOQ = 2.76 ng/band), and greener over NP procedure. The results of greenness assessment using NEMI (all four circles green), AES (93), ChlorTox (0.88 g), and AGREE (0.89) demonstrated that the RP strategy was greener than NP strategy and all other reported HPLC methods. The fact that both techniques can assess LMB when its degradation products are present implies that they both have characteristics that point to stability-indicating features. 89.24 % and 98.79 %, respectively, were the assay results for LMB in pharmaceutical tablets when utilizing the NP and RP procedures. Based on all validation and greenness metrics, it was found that RP procedure was better than the NP procedure. As a result, it is possible to assess LMB in pharmaceutical products using RP procedure.

Details

Journal
Arabian Journal of Chemistry
Publisher
Elsevier BV
Volume
17
Issue
7
Pages
105837-105837
ISSN
1878-5352
Year
2024
Language
en
License
cc-by-nc-nd
Open access
hybrid
Citations
3
Source
scopus

Topics

ChemistryChromatographyStationary phaseHigh performance thin layer chromatographyThin-layer chromatography

Analytical Methods in Pharmaceuticals (Chemistry) · Analytical Chemistry and Chromatography (Chemistry) · Forensic Toxicology and Drug Analysis (Pharmacology, Toxicology and Pharmaceutics)

Cite this

APA
Aljarba, T. M., Shakeel, F., Alshehri, S., Iqbal, M., Foudah, A. I., Alqarni, M. H., Alhaiti, A., Bar, F. M. A., Alam, P. (2024). Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis. Arabian Journal of Chemistry, 17(7), 105837-105837. https://doi.org/10.1016/j.arabjc.2024.105837
Harvard
Aljarba, T. M., Shakeel, F., Alshehri, S., Iqbal, M., Foudah, A. I., Alqarni, M. H., Alhaiti, A., Bar, F. M. A., Alam, P. 2024, 'Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis', Arabian Journal of Chemistry, vol. 17(7), 105837-105837. Available at: https://doi.org/10.1016/j.arabjc.2024.105837
Vancouver
Aljarba TM, Shakeel F, Alshehri S, Iqbal M, Foudah AI, Alqarni MH, Alhaiti A, Bar FMA, Alam P. Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis. Arabian Journal of Chemistry. 2024;17(7), 105837-105837.
BibTeX
@article{aljarba20241372,
  title = {Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis},
  author = {Tariq Mohammed Aljarba and Faiyaz Shakeel and Sultan Alshehri and Muzaffar Iqbal and Ahmed Ibrahim Foudah and Mohammed Hamed Alqarni and Ali Alhaiti and Fatma Mohamed Abdel Bar and Prawez Alam},
  year = {2024},
  journal = {Arabian Journal of Chemistry},
  volume = {17},
  number = {7},
  pages = {105837-105837},
  publisher = {Elsevier BV},
  doi = {10.1016/j.arabjc.2024.105837},
  url = {https://doi.org/10.1016/j.arabjc.2024.105837}
}
RIS
TY  - JOUR
AU  - Tariq Mohammed Aljarba
AU  - Faiyaz Shakeel
AU  - Sultan Alshehri
AU  - Muzaffar Iqbal
AU  - Ahmed Ibrahim Foudah
AU  - Mohammed Hamed Alqarni
AU  - Ali Alhaiti
AU  - Fatma Mohamed Abdel Bar
AU  - Prawez Alam
TI  - Contrasting the validation parameters and greenness of normal-phase and reverse-phase stability-indicating HPTLC methods for lemborexant analysis
PY  - 2024
JO  - Arabian Journal of Chemistry
VL  - 17
IS  - 7
SP  - 105837-105837
DO  - 10.1016/j.arabjc.2024.105837
UR  - https://doi.org/10.1016/j.arabjc.2024.105837
ER  - 

Related outputs