جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

2 مُخرَج نتائج البحث عن «915 MHz»

مقالوصول مفتوح20253استشهاد· Semantic Scholar

A Compact Implantable Multiple-Input-Multiple-Output Antenna for Biotelemetry and Sensing Applications

Sensors · مجلد 25 (11) · 3323-3323

Gastrointestinal (GI) tract diseases are among the most common diseases in the world, resulting in more than 8 million deaths. The majority of these deaths occur due to cancer or tumors. Early detection of these tumors can greatly lower the mortality rate. In this work, an implantable multiple-input-multiple-output (MIMO) antenna sensor is constructed for GI tract devices to detect the tumor. The implantable MIMO antenna sensor has two embedded antennas, each operating at 915 MHz. Both elements of the system are placed 0.6 mm apart from each other (edge-to-edge). The volume consumed by this design is measured to be 7 × 7 × 0.25 = 12.25 mm3. It occupies a very small volume due to miniaturization achieved using meandered resonating structures and a high-permittivity substrate. It maintains stable radiation performance (gain = −26.2 dBi at resonance). The antenna units are decoupled by maintaining a proper gap between them and adding a slot on the bottom side. An isolation level greater than 28.7 dB is achieved using these approaches. Since the MIMO system utilizes two antenna elements, its effectiveness is verified using MIMO parameters. At SNR = 20 dB, the channel capacity reaches 8.75 bps/Hz. The proposed antenna ensures high channel capacity and enables seamless communication while simultaneously acting as a sensor to monitor internal changes in the observed region. The frequency response change with variations in the permittivity of human tissue, enabling its sensing capability. Moreover, the antenna sensor maintains stable radiation and S-parameter performance throughout the sensing mechanism. Thus, the proposed solution is suitable for biomedical implants requiring both high-data-rate communication and sensing.

implantable antennaMIMO antennaantenna sensorbiotelemetry
مقالوصول مفتوح202439استشهاد· Semantic Scholar

Optimization of a Compact Wearable LoRa Patch Antenna for Vital Sign Monitoring in WBAN Medical Applications Using Machine Learning

IEEE Access · مجلد 12 · 103860-103879

This study introduces an innovative and compact wearable Long-Range (LoRa) patch antenna developed for monitoring vital signs, with a focus on heart rate and body temperature, in medical applications of Wireless Body Area Networks (WBAN). The antenna functions within the 868 MHz and 915 MHz LoRa bands, filling a notable gap in current literature regarding compact, wearable antennas operating below 1 GHz. Fabricated on a Rogers Duroid RO3003 substrate, the antenna incorporates a U-slot on a conventional rectangular patch, a matching stub, and a partial ground plane to enhance impedance matching and performance efficiency. Furthermore, the antenna displays a bidirectional radiation pattern in the E-plane and an omnidirectional pattern in the H-plane at both frequencies, achieving a peak gain of 2.12 dBi and a radiation efficiency of 99.8% at 868 MHz. The antenna, measuring$80 \times 60 \text {mm}^{2}$($0.23~\lambda _{0} \times 0.17~\lambda _{0}$), was designed, simulated, and optimized using CST Microwave Studio (MWS) software. The performance under bending conditions was also assessed, revealing a bending an excellent efficiency with minimal impact on bandwidth and gain. Specific Absorption Rate (SAR) analysis indicated that all values were within the safety limits set by FCC and ICNIRP standards. Supervised regression machine learning models, specifically the ensemble regression model, were employed to predict resonance frequencies based on various antenna parameters, resulting in an R-squared score of 87.68%. This approach significantly reduced the computational time required for full-wave simulations, streamlining the design process. Real-world experimental validation involved open-field testing of the fabricated prototype for WBAN LoRa applications. The performance, evaluated on a LoRa transceiver system utilizing the LoRa SX1276, demonstrated the superior capabilities of the proposed antenna in heart rate and temperature monitoring, with an average RSSI improvement of -5 dBm at various points within a range of up to 1 km. This confirmed its improved signal transmission and reception capabilities in vital sign monitoring. The proposed antenna shows strong performance metrics and significant potential for WBAN in long-range applications, as evidenced by thorough experimental validations.

LoRawireless body area networksvital signs monitoringheart rate monitoring