We present a modular microfluidic platform for constructing miniaturized, compartmentalized cell culture systems that support monoculture, co-culture, and organ-on-a-chip models of human tissues. The devices provide architecturally defined three-dimensional microenvironments in which heterogeneous cell populations can be cultured in close proximity while maintaining precise spatial organization and independent access to each compartment. In vivo-like perfusion into, from, and between adjacent chambers is achieved via micro-engineered porous barriers that act as perfusion microchannels, enabling controlled convective and diffusive transport and recapitulating paracrine signaling between tissue units. As a proof of concept, we implement an adipose-immune co-culture model that reproduces key features of inflamed, insulin-resistant adipose tissue, including altered cytokine secretion and glucose uptake. Together, these features establish a versatile platform for the biofabrication of customizable single-organ and multi-organ in vitro models that more faithfully recapitulate human tissue structure and function for applications in disease modeling, immunometabolic studies, and preclinical drug testing.
In this work, the design and experimental validation of passive UHF RFID tag antennas are presented with the objective of evaluating the impact of chip placement and miniaturization approaches on tag performance. Four initial antenna layouts were developed by varying the position of the RFID integrated circuit within a coupling loop. The results show that chip placement directly affects the coupling-loop efficiency, the antenna-chip matching condition, and the practical tolerance of the structure to fabrication-related variations. Simulations and measurements identified Antenna 1 as the best-performing reference configuration, exhibiting the most favorable impedance behavior around 866 MHz and a measured power sensitivity of -16.3 dBm. Based on this reference design, a miniaturized version (Antenna 5) was obtained by integrating meander lines and capacitive end-loading, reducing the physical size while maintaining resonance at 866 MHz. Both structures were fabricated and evaluated using a Voyantic Tagformance measurement system, with read-range measurements performed under free-space conditions and in proximity to dielectric and conductive materials. The results demonstrate a maximum read range of 8.6 m for Antenna 1 in free space, while Antenna 5 preserved a read range of 6.3 m. In the presence of copper, Antenna 1 maintained a read range of 3 m, whereas Antenna 5 achieved approximately 0.5 m, highlighting the trade-off between miniaturization and robustness under conductive loading.
UHF RFID tag antennaflexible antennameandered antennachip placement
A versatile and modular microfluidic system for cell co-culture has been developed. Microfluidic chips, each featuring dual compartments separated by a porous membrane, have been fabricated and assembled within the system to facilitate fluidic interconnection and cell-cell communication through the chip assembly. A set of fluidic valves has been successfully integrated to regulate the flow through the chip assembly. The system allows for chip assembly in various arrangements, including in parallel, in series, and complex connections. Individual chips can be interconnected or disconnected within the system at any time. Moreover, the spatial order and orientation of the chips can be adjusted as needed, enabling the study of different cell-cell arrangements and the impact of the presence or absence of specific cell types. The utility of the system has been evaluated by culturing and interconnecting multi-monolayers of intestinal epithelial cells as a model of the complex cellular system. Epithelial monolayers were grown in multiple chips and interconnected in various configurations. The transepithelial electrical resistance and permeability profiles were investigated in detail for these configurations upon treatment of the cells with dextran sulfate sodium. Immune cells were stimulated through the epithelial layers and the expression of inflammatory cytokines was detected. This miniaturized platform offers controlled conditions for co-culturing key cellular components and assessing potential therapeutic agents in a physiologically relevant setting.
modular microfluidic systemco-culturefluidic valvesintercellular communication
A modular organ-on-a-chip (OOC) system has been developed, incorporating multiple epithelial barriers and perfused immune cells, and enabling the monitoring of the structure, integrity, and response of the barriers to activation.Additionally, it facilitates the examination of the complex interaction between multi-epithelial barriers with immune cells.Fig. 1a schematically illustrates the system, while Fig. 1b provides details of the microfluidic chip connections and Fig. 1c shows the fabricated system.Triple intestinal barriers and intestinal and epidermal barriers were integrated and characterized.OOC technology enables precise cell positioning and in vivo-like polarization, mimicking tissue organization.While organoids provide multicellular structures, more advanced methods are required to induce cellular assemblies and recreate the extracellular environment [1].Epithelial cell polarity, regulated by tight junction (TJ) formation, is crucial for various barriers [2].Microfluidic-based cell culture seamlessly integrates diverse cell types and organs into a unified fluidic circuit.We previously developed a reconfigurable fluidic routing system for inter-chip communication [3].Here, we present an enhanced system that effectively regulates multiple fluidic parameters and enables flexible chip-to-chip interconnections, allowing for fluid redirection across different spatial and temporal dimensions without compromising the flow in other chips.To demonstrate the versatility of MOOCS, three intestinal cell monolayers were integrated into a single fluidic circuit (Fig. 2a), and the TransEpithelial Electrical Resistance (TEER) resulting from the different linkages was measured.Both the individual and the interconnected monolayers displayed stable and increasing TEER values (Fig. 2b).After 20 days, the chips were interconnected, and 100 µL of DSS (5000 Da) was injected into one chip, leading to a decline in the total TEER.However, upon disconnecting the affected layer, the TEER returned to its initial level.This experimental setup allows for the execution of multiple experiments on the same cell culture by selectively eliminating the impacted cells.Then, three culture systems were tested: immune cells (THP-1), intestinal/immune cells (Caco-2/THP-1), and epidermal/immune cells (HaCaT/THP-1).Interactions with inflammation stimuli (LPS and DSS) were studied in interconnected/disconnected cellular systems (Fig. 3a).TEERs of disconnected layers increased over time (Fig. 3b).Caco-2 and HaCaT cultures were treated with DSS, showing significant cytotoxicity, especially in caco-2 cells (Fig. 3c).FITC-dextran (4 kDa) flux measurements revealed increased permeability when LPS was applied to Caco-2, HaCaT, or both layers (Fig. 3d).To investigate the response of the integrated cellular system, immune cells were activated by direct activation with LPS, activation through the caco-2 layer with LPS, activation through the HaCaT layer with DNCB, and activation through both layers with LPS and DNCB, respectively.IL-6 and IL-8 expression were measured in the basolateral compartment.Both LPS and DNCB induced significant immune cell responses, with direct treatment showing a higher inflammatory response compared to treatment through the caco-2/HaCaT layers.These findings highlight the successful integration of epithelial cell layers and their interaction with immune cells, providing a valuable model for studying drug screening.This system allows for flexible integration strategies of diverse cellular systems, enabling the investigation of cellular interactions when stimulated through various routes.
Studying the immune system in vitro aims to understand how, when, and where the immune cells migrate/differentiate and respond to the various triggering events and the decision points along the immune response journey. It becomes evident that organ-on-a-chip (OOC) technology has a superior capability to recapitulate the cell-cell and tissue-tissue interaction in the body, with a great potential to provide tools for tracking the paracrine signaling with high spatial-temporal precision and implementing in situ real-time, non-destructive detection assays, therefore, enabling extraction of mechanistic information rather than phenotypic information. However, despite the rapid development in this technology, integration of the immune system into OOC devices stays among the least navigated tasks, with immune cells still the major missing components in the developed models. This is mainly due to the complexity of the immune system and the reductionist methodology of the OOC modules. Dedicated research in this field is demanded to establish the understanding of mechanism-based disease endotypes rather than phenotypes. Herein, we systemically present a synthesis of the state-of-the-art of immune-cantered OOC technology. We comprehensively outlined what is achieved and identified the technology gaps emphasizing the missing components required to establish immune-competent OOCs and bridge these gaps.
Human Vaccines & Immunotherapeutics · مجلد 18 (1) · 2031455-2031455
A qualitative exploration of pharmacists’ perceptions regarding COVID-19 conspiracies and their willingness to get vaccinated. A semi-structured questionnaire guide was developed using ground theory to conduct in-depth interviews. A total of 36 participants gave consent for an audio-recorded interview. Results have shown that most of the respondents believed that SARS-CoV-2 is a natural virus, not man-made, that causes a disease just like other viruses and it is absurd to believe that the vaccine is being used by foreign powers for the implantation of microchips just to control humans. A general opinion thatwhich reflected from the in-depth interview is that the pharmaceutical companies may be hiding some important information on COVID-19 to promote the sale of their product. Some doubts on the reliability and trustworthiness on the COVID-19 vaccine safety and efficacy data were noticed among the respondents. Factors leading to COVID-19 vaccine hesitancy were adverse reaction, cost of COVID-19 vaccine, and limited data on safety and efficacy profile of COVID-19 vaccine. COVID-19 vaccine hesitancy among health professionals is a major hindrance to our current fight against COVID-19 pandemic. Findings of this study are alarming, and the stakeholders must consider this ongoing vaccination campaign as an opportunity to formulate a mechanism to ensure high vaccination rate among general public and healthcare providers in Pakistan.KEY POINTSWhat was already known?According to World Health Organization (WHO), vaccine hesitancy is one of the ten major threats to global healthcare system and it is a major barrier to achieve herd immunity around the globe.Pakistan has begun vaccinating its people in a systematic phase-wise manner under which the healthcare workers and elderly people are prioritized for vaccination.Previous experience tells us that vaccine hesitancy is a major problem in Pakistan and it is better to understand perceptions of pharmacists about COVID-19 vaccine who are the primary source of information for most of general population.What this study adds:This study is first of its kind to explore vaccine hesitancy among Pakistani pharmacists and the results of this study show that majority of the participants were willing to get COVID-19 vaccine and few of them have even got themselves vaccinated at the start of vaccination campaign.Many among the willing participants considered cost of vaccine, adverse reactions, limited data, safety, and efficacy as major hindrance to their decision to get vaccine.Few participants were found highly vaccine-hesitant because of their staunch belief in the prevalent myths and rumors about COVID-19 vaccine.
Despite many ongoing efforts across the full spectrum of pharmaceutical and biotech industries, drug development is still a costly undertaking that involves a high risk of failure during clinical trials. Animal models played vital roles in understanding the mechanism of human diseases. However, the use of these models has been a subject of heated debate, particularly due to ethical matters and the inevitable pathophysiological differences between animals and humans. Current in vitro models lack the sufficient functionality and predictivity of human pharmacokinetics and toxicity, therefore, are not capable to fully replace animal models. The recent development of micro-physiological systems has shown great potential as indispensable tools for recapitulating key physiological parameters of humans and providing in vitro methods for predicting the pharmacokinetics and pharmacodynamics in humans. Integration of Absorption, Distribution, Metabolism, and Excretion (ADME) processes within one close in vitro system is a paramount development that would meet important unmet pharmaceutical industry needs. In this review paper, synthesis of the ADME-centered organ-on-a-chip technology is systemically presented from what is achieved to what needs to be done, emphasizing the requirements of in vitro models that meet industrial needs in terms of the structure and functions.
A biologically guided isolation of secondary metabolites from Cousinia alata Schrenk wild plant growing in Akmola region, Kazakhstan, led to the isolation of the bioactive diterpene grindelic acid (1). Six flavonoids were also isolated and identified as retusine (2), pachipodol (3), jaranol (4), penduletin (5), casticin (6), and 5, 7, 3′-trihydroxy-3, 4′-dimethoxyflavone (7). Penduletin (5) showed moderate cytotoxic activity assay. Grindelic acid exhibited promising cytotoxic activity against the Artemia salina nauplii and antibacterial activity against Staphylococcus aureus, Bacillus cereus, and Salmonella enteritidis. The presence of the essential pharmacophoric features of histone deacetylase (HDAC) inhibitors in the structure of grindelic acid encouraged us to run a molecular docking study against the HDAC enzyme to understand its mechanism of action on a molecular level. Grindelic acid showed a binding mode of interaction similar to that of the cocrystallized ligand and exhibited good binding affinity against HDAC with the binding free energy of −18.70 kcal/mol. The structures of isolated compounds were determined by MS, 1D, and 2D NMR spectroscopy methods. Compounds (1–7) were isolated for the first time from Cousinia genus.