جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

2 مُخرَج نتائج البحث عن «Fluoroscopy»

مراجعةوصول مفتوح2026

Pulsed field ablation versus cryoballoon ablation for pulmonary vein isolation in atrial fibrillation: a systematic review and meta-analysis with subgroup analyses by AF type

BMC Cardiovascular Disorders · مجلد 26 (1)

BACKGROUND: Pulsed field ablation (PFA) is a non-thermal alternative to cryoballoon ablation (CBA) for pulmonary vein isolation in atrial fibrillation (AF). We compared their procedural efficiency, safety, and 1-year outcomes. METHODS: We searched PubMed, Scopus, Web of Science, CENTRAL, and Embase through October 2025 for randomized and comparative cohort studies of adults undergoing PFA or CBA. Outcomes were procedure duration, fluoroscopy time, left-atrial dwell time, periprocedural complications, and 1-year atrial arrhythmia recurrence, synthesized using random-effects meta-analyses with AF-type subgroup analyses. RESULTS: Twenty-three studies were included overall, of which 22 contributed to the quantitative synthesis. Overall, PFA shortened procedure duration versus CBA (mean difference [MD] − 11.50 min, 95% confidence interval [CI] − 15.39 to − 7.62), driven by persistent and mixed AF subgroups, while no significant difference was observed in paroxysmal AF. LA dwell time was reduced with PFA in paroxysmal AF, whereas fluoroscopy time did not differ significantly overall. Stroke, bleeding, and cardiac tamponade were comparable. PFA markedly decreased persistent (risk ratio [RR] 0.31, 95% CI 0.10–0.91) and transient (RR 0.19, 95% CI 0.07–0.53) phrenic nerve palsy. At 1 year, overall pooled analyses showed lower total atrial arrhythmia recurrence (RR 0.79, 95% CI 0.66–0.94) and AF recurrence (RR 0.72, 95% CI 0.62–0.83), with no difference in atrial flutter recurrence. CONCLUSIONS: PFA appears to offer shorter procedures and a more favorable phrenic-nerve safety profile than cryoballoon ablation, without evidence of excess major complications. Apparent 1-year efficacy advantages should be interpreted cautiously because the evidence base is dominated by observational studies and direct randomized PFA-versus-cryoballoon evidence remains limited.

pulsed field ablationcryoballoon ablationpulmonary vein isolationatrial fibrillation
مقالوصول مفتوح20238استشهاد· Semantic Scholar

Fluoroscopy-Guided Metallic Foreign Body Removal: A Report of Three Cases and Literature Review

Cureus · مجلد 15 (6) · e40462-e40462

Ingested foreign objects that become trapped in the upper aerodigestive tract is a common issue that arises in Otolaryngology-Head and Neck Surgery practice. In these circumstances, it is advised to explore the neck using an external method to remove the item. However, locating the foreign body might be challenging. Not all metallic foreign body (MFB) patients require surgery, especially those without symptoms or complications. The standard X-ray and CT images are routinely examined for preoperative assessment and localization. Removal can be accomplished via flexible pharyngo-laryngoscopy or upper gastrointestinal endoscopy. Fluoroscopy is a widely accessible, minimally invasive, but underutilized tool during procedures. It offers an accurate intraoperative assessment of the foreign body in real-time. To allow the planning of a secure extraction pathway, the target should be radiopaque. In this report, we present three unique cases in which we used fluoroscopic imaging for guidance to remove a foreign body in the head and neck region in Prince Sultan Military Medical City in Riyadh, Saudi Arabia. In the first case, a young male presented with a history of foreign body sensation and odynophagia in the throat after eating a (shawarma) sandwich. In the second case, a six-year-old boy presented to the emergency department (ED) with epistaxis after being exposed to an air gun shot to his face. In the third case, a 40- year-old male presented after exposure to an air gun shot to the neck. After identification of the foreign body, all three patients were referred to Otolaryngology-Head and Neck. After radiological images have been done to confirm the presence of foreign objects, all three had a minimally invasive procedure to remove the metallic foreign bodies under fluoroscopic guidance without needing extensive surgery. All the procedures went well with no immediate complications with discharge on the same day. Fluoroscopy-guided removal of foreign bodies related to metabolic forging is a promising technique with several advantages, including real-time visualization, reduced invasiveness, and shorter recovery times. However, it is essential to weigh the benefits against the risks associated with radiation exposure and inherent limitations in detecting non-metallic objects. Further research and clinical studies are needed to optimize this technique and establish evidence-based guidelines for its application in the field of metabolic forging bodies.

foreign body ingestionupper aerodigestive tractair gun injuryepistaxis