جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

3 مُخرَج نتائج البحث عن «Funnel plot»

ملخص مؤتمروصول مفتوح2026

Diagnostic Accuracy of Modalities For Acute Heart Failure In Emergency Settings. A Systematic Review and Diagnostic Accuracy Meta-Analysis

Saudi Journal of Emergency Medicine · مجلد 7 (1S) · 91-91

Background: Acute heart failure diagnosis in emergency departments remains challenging despite multiple available diagnostic modalities. Current emergency evaluations rely variably on clinical assessment, biomarkers, and ultrasound techniques; however, their comparative diagnostic accuracy remains inadequately compared in previous studies. This systematic review and meta-analysis aim to evaluate the diagnostic accuracy of four categories of diagnostic approaches: Clinical Assessment, Biomarker Assessment, Basic Ultrasound Assessment, and Advanced Ultrasound Assessment for diagnosing acute heart failure in emergency settings. Methods: We conducted a literature review across PubMed/MEDLINE, Scopus, Google Scholar, Cochrane Library, Google Scholar, and Web of Science up to December 2024. Studies investigating the diagnostic modalities for acute heart failure in emergency settings with sufficient data to construct 2×2 contingency tables were included. Two independent reviewers performed screening, data extraction, and quality assessment using QUADAS-2. Diagnostic accuracy was synthesized using a bivariate random-effects model. Summary receiver operating characteristic (SROC) curves, pooled sensitivity, specificity, and area under the curve (AUC) were calculated with 95% confidence intervals (CI). Heterogeneity was assessed using I² statistics and publication bias with Deeks' funnel plot. Results: Thirty-three studies including a total of 17 participants to 1,586 participants met the inclusion criteria. Clinical Assessment demonstrated moderate diagnostic performance (AUC=0.591) with limited sensitivity (0.500, 95% CI: 0.484-0.515) but high specificity (0.858, 95% CI: 0.830-0.886). Biomarker Assessment showed excellent performance (AUC=0.906) with high sensitivity (0.874, 95% CI: 0.872-0.875) and good specificity (0.781, 95% CI: 0.778-0.783). Basic Ultrasound Assessment had moderate performance (AUC=0.750) with low sensitivity (0.349, 95% CI: 0.303-0.395) but high specificity (0.889, 95% CI: 0.874-0.904). Advanced Ultrasound Assessment demonstrated excellent performance (AUC=0.892) with good sensitivity (0.713, 95% CI: 0.705-0.720) and very high specificity (0.903, 95% CI: 0.900-0.905). All modalities showed remarkably consistent performance across studies (I²=0%). Conclusion: Biomarker Assessment provides the highest overall diagnostic accuracy for acute heart failure in emergency settings, while Advanced Ultrasound Assessment offers the optimal balance between sensitivity and specificity when equipment and expertise are available. Clinical Assessment alone has limitations for detecting acute heart failure but remains useful for exclusion. Our findings highly recommend adapting a multimodal diagnostic approach integrating biomarkers and advanced ultrasound techniques whenever possible for optimal diagnostic accuracy in emergency settings.

acute heart failureemergency diagnosisdiagnostic accuracyclinical evaluation
مراجعةوصول مفتوح2026

Clinical utility of artificial intelligence in prehospital emergency medical services : a systematic review and meta-analysis

Universa Medicina · مجلد 45 (2) · 294-309

BackgroundThe emergency medical services (EMS) sector presents substantial hurdles in providing excellent treatment while operating within limited resources. Artificial intelligence (AI) has significant potential in prehospital EMS, where rapid and accurate decision-making is essential. However, a comprehensive synthesis of AI’s effectiveness in this setting remains limited. The objective of this systematic review and meta-analysis was to evaluate AI’s predictive accuracy, compare its performance with human-based triage, and assess its feasibility in prehospital care. MethodsFollowing PRISMA guidelines, PubMed, Cochrane Library, and Web of Science were searched up to February 20, 2025. Fourteen peer-reviewed studies reporting quantitative outcomes were included. Study quality was assessed using the Newcastle-Ottawa Scale (median score = 7). Random-effects meta-analyses in R were conducted to synthesize area under the curve (AUC), AI-human AUC differences, and feasibility outcomes. ResultsAcross 14 studies involving 9,107,906 patients, AI demonstrated strong predictive performance with a pooled AUC of 0.874 (95% CI: 0.843–0.905). Individual study AUCs ranged from 0.805 to 0.997, with moderate heterogeneity (I²=52.3%). In eight studies, AI significantly outperformed human triage, showing a pooled AUC improvement of 0.074 (95% CI: 0.045–0.103; p<0.001), despite high heterogeneity due to varying human benchmarks. Feasibility analysis showed high clinical utility, with a pooled proportion of 0.929 and no heterogeneity (I²=0%). Funnel plots suggested slight asymmetry, but Egger’s tests indicated no significant publication bias. ConclusionArtificial intelligence demonstrated high predictive accuracy, slight superiority over human triage, and strong feasibility in prehospital care, supporting its integration into EMS with further validation and standardized reporting.

artificial intelligenceprehospital emergency medical servicesemergency medical triageprediction accuracy
مراجعةوصول مفتوح2025

Evaluating artificial intelligence for accurate detection of hand and wrist fractures: a systematic review and meta-analysis

F1000Research · مجلد 14 · 1062-1062

Background and Objectives Hand and wrist fractures are among the most frequently encountered injuries in emergency departments and are often misdiagnosed, particularly when interpreted by non-specialist clinicians. These diagnostic errors can lead to treatment delays and long-term complications. Artificial intelligence (AI), particularly deep learning algorithms, is emerging as a promising adjunct to improve diagnostic accuracy in radiographic fracture detection. This study aims to evaluate the effectiveness of Artificial Intelligence (AI) in detecting hand and wrist fractures compared to manual radiographic interpretation by clinicians. Materials and Methods A systematic review and meta-analysis were conducted to assess the diagnostic performance of AI models in detecting hand and wrist fractures compared to conventional radiographic interpretation by clinicians. A comprehensive search of PubMed, Google Scholar, Science Direct, and Wiley Online Library was performed. Eligible studies included those utilizing AI for fracture detection with sensitivity and specificity data. Pooled estimates were calculated using fixed- and random-effects models. Heterogeneity was assessed via I 2 statistics, and publication bias was examined using funnel plots and Egger’s test. Results Eighteen studies met inclusion criteria. The pooled sensitivity and specificity under the random-effects model were 0.910 and 0.912, respectively, indicating high diagnostic accuracy of AI models. However, substantial heterogeneity (I 2 = 99.09% for sensitivity; 96.43% for specificity) and publication bias were observed, likely due to variations in AI algorithms, sample sizes, and study designs. Conclusions Most AI models demonstrated good diagnostic accuracy, with high sensitivity and specificity scores (≥90%). However, some models fell short in sensitivity and specificity (≤90%), indicating performance variations across different AI models or algorithms. From a clinical perspective, AI models with lower sensitivity scores may fail to detect hand and wrist fractures, potentially delaying treatment, while those with lower specificity scores could lead to unnecessary interventions—treating hands and wrists that are not fractured.

hand fractureswrist fracturesartificial intelligencedeep learning