جامعة المعرفة
المصدر المعتمد للمعلومات البحثية والمخرجات هو قاعدة بيانات سكوبس (Elsevier Scopus) مع تدقيق بيانات الباحثين من عمادة البحث العلمي.

Research outputs

المخرجات البحثية

مقالات ومراجعات وأوراق مؤتمرات وفصول كتب، مفهرسة برقم DOI ومربوطة بباحثي الجامعة.

3 مُخرَج نتائج البحث عن «image enhancement»

مقالوصول مفتوح202327استشهاد· Semantic Scholar

Developing a Deep-Learning-Based Coronary Artery Disease Detection Technique Using Computer Tomography Images

Diagnostics · مجلد 13 (7) · 1312-1312

Coronary artery disease (CAD) is one of the major causes of fatalities across the globe. The recent developments in convolutional neural networks (CNN) allow researchers to detect CAD from computed tomography (CT) images. The CAD detection model assists physicians in identifying cardiac disease at earlier stages. The recent CAD detection models demand a high computational cost and a more significant number of images. Therefore, this study intends to develop a CNN-based CAD detection model. The researchers apply an image enhancement technique to improve the CT image quality. The authors employed You look only once (YOLO) V7 for extracting the features. Aquila optimization is used for optimizing the hyperparameters of the UNet++ model to predict CAD. The proposed feature extraction technique and hyperparameter tuning approach reduces the computational costs and improves the performance of the UNet++ model. Two datasets are utilized for evaluating the performance of the proposed CAD detection model. The experimental outcomes suggest that the proposed method achieves an accuracy, recall, precision, F1-score, Matthews correlation coefficient, and Kappa of 99.4, 98.5, 98.65, 98.6, 95.35, and 95 and 99.5, 98.95, 98.95, 98.95, 96.35, and 96.25 for datasets 1 and 2, respectively. In addition, the proposed model outperforms the recent techniques by obtaining the area under the receiver operating characteristic and precision-recall curve of 0.97 and 0.95, and 0.96 and 0.94 for datasets 1 and 2, respectively. Moreover, the proposed model obtained a better confidence interval and standard deviation of [98.64-98.72] and 0.0014, and [97.41-97.49] and 0.0019 for datasets 1 and 2, respectively. The study's findings suggest that the proposed model can support physicians in identifying CAD with limited resources.

coronary artery disease detectionCT imagesconvolutional neural networksU-Net
مقالوصول مفتوح20239استشهاد

Building an Acute Ischemic Stroke Identification Model Using a Deep Learning Technique

Journal of Disability Research · مجلد 2 (1)

Acute ischemic stroke (AIS) is a leading cause of mortality and disability. Over the past several decades, researchers proposed multiple techniques to enhance the effectiveness of AIS diagnosis. Magnetic resonance imaging (MRI) and computed tomography (CT) are widely used for assessing and treating AIS. In recent years, healthcare centers have applied the deep learning–based technique to support physicians in identifying diseases at earlier stages. Recently, researchers have employed convolutional neural network (CNN)-based image classifiers to detect diseases using complex images. However, the models demand high computation resources for generating a reasonable outcome. Thus, this study intends to build a fine-tuned CNN model for identifying AIS from MRI and CT images. The proposed framework contains three phases: image enhancement, feature extraction, and fine-tuned detection model. Initially, the researcher applies an image colorization technique using generative adversarial networks. You only look once V7 is used to extract the images’ features. In the second phase, the authors employed the Aquila optimization algorithm for tuning the hyperparameters of the Residual Network with Split attention (ResNest) model. To evaluate the performance of the ResNest model, the authors utilized two benchmark datasets of brain MRI and CT images. The MRI datasets contain 1021 healthy and 955 unhealthy images, whereas the CT datasets comprise 1551 healthy and 950 unhealthy images. The findings reveal that the ResNest model outperforms the recent approaches. The model achieves an average accuracy and F 1 score of 98.25 and 97.275, and 98.65 and 98.25, for the MRI and CT datasets, respectively. In addition, the ResNest model obtained a confidence interval score of [97.84-98.13] and [97.91-98.52] for the MRI and CT datasets, respectively. The study uniquely develops a lightweight application through a compelling data preprocessing and feature extraction technique. In addition, the fine-tuned ResNest model achieves a superior outcome with limited resources. Healthcare centers can implement this lightweight model for diagnosing AIS patients.

acute ischemic strokestroke detectionbrain MRIbrain CT
ورقة مؤتمروصول مغلق20232استشهاد· Semantic Scholar

Classification of Fluid Filled Abnormalities In Retinal Optical Coherence Tomography Images Using Chicken Swarm Optimized Deep Learning Classifier

International Conference on Electrical, Computer, Communications and Mechatronics Engineering (ICECCME) · 1-8

Optical Coherence Tomography is a noncontact, non-invasive imaging regarded as the best diagnostic approach when compared to other imaging techniques. It provides convenience along with high resolution and is an indispensable tool utilized for the retinal disease diagnosis in clinical practice. Among retinal diseases, the vision loss is very common caused because of deficit or excess of fluid within the retinal layers. High risk for vision loss occurs due to such damages or deformations in the layers of retina. To tackle this, a deep learning approach is opted for diagnosing fluid filled abnormalities in retinal OCT images. The input image is enhanced by means of CLAHE approach and the retinal layer is segmented for the extraction and selection of relevant features. Gabor filter is adopted for the feature extraction and the selected features are further classified by RNN classifier whose parameters are trained by CSO approach. The utilized RNN provides dynamic system modelling and real-time big data classification. The proposed CSO efficiently trains the RNN parameters with increased accuracy and less time complexity .The NEH OCT image dataset is used in MATLAB to validate the proposed approach. The obtained results demonstrate the efficacy of the proposed approach with an accuracy of 95% and reduced processing time of 545.4s.

optical coherence tomographychicken swarm optimizationrecurrent neural networksretinal layer segmentation