The authoritative source for research information and outputs is Elsevier Scopus, with researcher profile verification from the Deanship of Scientific Research.
Background: Medication turnaround time (TAT) is a critical metric for evaluating the efficiency and safety of hospital pharmacy operations. Optimizing TAT is essential to ensure patient safety, reduce medication errors, enhance workflow efficiency, enhance resource utilization and enhance both the continuity of care and patient satisfaction. Aim: To discuss the important of TAT, factors influencing medication TAT and provide evidence-based recommendations to optimize medication delivery thereby improve patient care. Methods: A comprehensive search of PubMed, Google Scholar, and ScienceDirect was conducted up to June 15, 2025. Eligible studies included if they were conducted in inpatient settings and reported medication TAT as outcome. Outpatient studies and those without relevant data were excluded. Data on study characteristics, interventions, and outcomes were extracted and summarized narratively; no meta-analysis was performed due to the heterogeneity of the studies. Results: Analysis identified several determinants of prolonged TAT included inefficient health IT systems, inadequate communication, staffing limitations, and inconsistent workflows. Effective interventions encompassed automation, workflow redesign, staff role optimization, and process standardization. These strategies consistently reduced TAT, with reported improvements of 10% to over 50%. Conclusion: TAT is a fundamental indicator to measure hospital pharmacy performance and improve patient outcomes. Addressing the barriers through evidence-based strategies can significantly streamline the medication use process. Optimizing medication TAT requires a multifaceted approach that include integrates technology, standardized workflows, and improve human factors. Evidence suggests these approaches not only enhance operational efficiency but also reduce errors, strengthen regulatory compliance, and ultimately improve patient safety as well as satisfaction.
International Journal of Clinical Medical Research · vol. 1 (1) · 28-35
Background: The objective of this study was to compare the cost of outpatient ferric carboxymaltose (FCM; Ferinject®) versus Iron sucrose complex (ISC; Ferosac®), two prevalent intravenous iron therapy used in the treatment of iron-deficiency anemia (IDA) in the Kingdom of Saudi Arabia (KSA) from a tertiary care hospital perspective. Methods: A retrospective study was performed for all patients who were administered FCM in the outpatient clinical setting at Prince Sultan Military Medical City from January 1, 2019, until December 31, 2019. The descriptive data was analyzed using Microsoft Excel 2019 (Microsoft Corporation, Redmond, WA, USA). The total cost of treatment reflected the cost of drugs, the cost of disposables for each infusion, drug monitoring costs during infusion, the cost of productivity loss, and patient traveling cost. Result: Overall, 993 patients with IDA, treated with FCM in 1,688 outpatient visits were recruited in the study. In the outpatient setting, the per annum cost of treatment was SAR 1,434,092.50 with FCM treatment and SAR 1,715,299.70 with ISC treatment, with a corresponding saving of 16.4% (SAR 281,207.20) with FCM. The cost savings with FCM treatment can be attributed to the reduced frequency of patient visits and corresponding reduction in drug monitoring costs (SAR 266,995.20;77.3%), loss of productivity per year (SAR 163,550.20; 77.3%), and cost of transportation per year (SAR 573,920.00; 77.3%). Conclusion: The use of FCM, as opposed to ISC resulted in a reduced number of iron infusions (4.4 visits for ISC as compared to one visit for FCM), accompanied by a reduction in the total cost. FCM may represent a cost-saving option compared with the existing alternative therapy used for the management of IDA in KSA.
International Journal of Clinical Medical Research · vol. 1 (1) · 12-18
Background: The aim is to present an electronic CPR calculator combined with CDSS (clinical decision support system) as a safer and faster method for CPR calculation than manual calculation. Methods: A group of 70 nurses were randomly selected to calculate a CPR card and then enter the patient data into the CPR calculator. The time needed to complete the calculations and the time needed to enter patient information into the CPR calculator were measured. In addition, the number of medication calculation errors were recorded. Result: The time to finish the CPR card manually was 00:08:31 minutes and the time to generate the CPR card electronically was 00:01:15. The number of nurses who made errors in manual calculation was 23, the total number of errors was 101. There were no errors with the calculator. Conclusion: The CPR calculator has provided an accurate (with no errors) and faster way to generate CPR cards compared to the manual method.
clinical decision support systemsmedication calculationmedication administration recordspediatric ward